Solution Type
Problem Resolution Sure
Solution
1541120.1
:
SL8500 - Error Messages 3902; 3807; 1202; 3988; 1213; 3906
Related Items |
- Sun StorageTek SL8500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Created from <SR 3-6951904185>
Applies to:
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Info 3902 "Host socket connection dropped - with exception"
Info 3807 "Listener registered" HBC
Error 1202 "Invalid parameter value"
Error 3988 "Communication io timeout - External"
Error 1213 "No slot at address"
Error 3906 "input packet dropped - packet dropped - duplicate sequence number"
Cause
This KB was generated by an ASR from the SL8500 Tape Library; If you have remote connection, get the log snapshot.
After getting the log snapshot from the library these are the alarms with their corresponding explanation.
2013-03-19T10:54:31.504 1.0.0.0.0 root default internal 0 info 3902 "Host socket connection dropped - with exception" Socket=10240065/50001/162.123.7.166 identifier=NonblockingSocket[addr=162.123.210.252port=44708localport=50001] Exception=java.io.IOException: read EOF closing socket HBC
2013-03-19T10:54:31.518 1.0.0.0.0 root default internal 0 info 3902 "Host socket connection dropped - socket closed" Socket=10240065/50001/162.123.7.166 identifier=NonblockingSocket[addr=162.123.210.252port=44708localport=50001] HBC
-This means the library manager, HSC/ACSLS, closed the communication socket to the library. This can happen for a variety of reasons but most often it occurs when HSC/ACSLS is doing network recovery.
2013-03-19T12:00:38.950 1.0.0.0.0 root default eventListen 10563930 info 3807 "Listener registered" HBC
-About an hour later a user logs into the library via SLC.
2013-03-19T12:01:18.295 1.0.0.0.0 root default getPartition 10564490 error 1202 "Invalid parameter value" parameter= GetPartitionState is not supported in the SL8500 platform
2013-03-19T12:01:24.773 1.0.0.0.0 root default getPartition 10564550 error 1202 "Invalid parameter value" parameter= GetPartitionState is not supported in the SL8500 platform
-The same version of SLC handles several different library types and this message can be ignored for the SL8500.
2013-03-19T12:09:38.028 7.37.6.1 root hli0 move 10564760 error 3988 "Communication io timeout - External" To=0 12=MsgLocation Seq=94030601 HBC
-Communication timeout on the ILC interface of the library which is used to talk with libraries in the same complex.
2013-03-19T12:09:38.038 1.0.0.0.0 root hli0 move 10564760 error 1213 "No slot at address" sourceAddress=73761 HBC
- Host Hli0 sent a move command to the library with an invalid destination address since it is an invalid address none of the library controllers would respond to this message and it would time out.
2013-03-19T12:10:38.237 1.0.0.0.0 root default internal 0 error 3906 "input packet dropped - packet dropped - duplicate sequence number"
-An Hli packet was sent to the library with a duplicate sequence number. The library assumes the original sequence number is still in process and drops the duplicate Hli packet. This usually happens when the library did not ACK the packet and HSC resends the original packet.
Solution
This recommendation was given by Bruce Mcdonald
Based on these error messages you would not be able develop an action plan because it is probably a symptom of others issues impacting the site. If the original problem reported by the customer is related to network recovery and losing access to the library.
Troubleshoot the library network configuration.