Applies to:Sun Blade T6340 Server Module - Version All Versions and laterInformation in this document applies to any platform. SymptomsSome T6340's with 1.2GHz or 1.4GHz x 8 Core has unexpected outage and SP event log shows Fault critical: "SP detected fault at time Tue Oct 27 18:17:32 2009. Host Power Failure: MB_DC_POK Fault" ChangesContributing Factors
CauseDC/DC converter noise problem triggers blade power shutdown. SolutionUpdate SysFw to v7.2.4.f (SUNPATCH 139448-05 or later), which contains the fix to filter out noise and prevent false power failure event. References<NOTE:1021650.1> - Sun Blade T6340 large blade configurations (1.2GHz or 1.4GHz x 8 core) show high fallout with power faults from CPU DC/DC converter.Attachments This solution has no attachment |
||||||||||||||||||||
|