![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1540243.1 : Some T6320 G2's could see "Chassis cover removed" messages which prevent blade power on
In this Document
Applies to:Sun Blade T6320 Server Module - Version All Versions and laterInformation in this document applies to any platform. SymptomsBlade can not be powered on and SP event logs show SP detected fault at time Mon Mar 1 18:25:27 2010. Chassis cover removed or in snapshot VBSC log ./ilom/@persist@vbsc@vbsc.log Mar 15 12:07:07 WARNING: Intrusion in system chassis
ChangesContributing Factors CauseFPGA defect SolutionThis issue is only seen on T6320 G2 with SP part 511-1304-06 (and earlier). If blade can not be powered on and SP event logs show: SP detected fault at time Mon Mar 1 18:25:27 2010. Chassis cover removed Replace SP with part 511-1304-08 (and later). Attachments This solution has no attachment |
||||||||||||||||||
|