![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1539881.1 : T10000C - Encountered FSC40AC, EOD Was Found in ALP Mode
In this Document
Created from <SR 3-6970719694> Applies to:StorageTek T10000C Tape Drive - Version Not Applicable and laterInformation in this document applies to any platform. SymptomsFSC Encountered: 40AC, drive did not SNO! FSC40AC, 40AC CauseEOD was found in ALP mode. FSC: 40AC |EOD FOUND |ALP MODE | *** | MIM Code: NONE FRU: STATUS ONLY CONF: 100% Field Text: EOD was found in ALP mode. SolutionSuggest to first attempt a REBUILD MIR on affected cartridge (which may take very long (days) depending on how full the cartridge's MVC is, as fuller the MVC is, the shorter the MVC MIR REBUILD will be. Recommend removing this tape from production and monitor this drive for additional FSC 40AC. Request customer to copy data to new tape and follow their media policy for tape replacement. Attachments This solution has no attachment |
||||||||||||||||
|