Symptoms
Changes
Cause
Solution
References


Created from <SR 3-6814624581>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

Note:
As each component is replaced, such as Robot, Op Panel, KLM. Serial number can be lost without a successful library initialization between part replacement. Reason is the flash stick housing library serial number are in these 3 locations and 2 of 3 flash sticks must match, otherwise library will not initialize without taking drastic steps of remotely re-programming the flash stick using Eng userid (only L2 and engineering) using webex session.

*** Workaround ***If for any reason the replacement part did not fix the problem and did not initialize library, put the original part back in and capture a log bundle. Engage L2 support before replacing another part.

Symptoms

Final code 9081:
Decoded:
9081 MAG_MULTIPLE_OPEN_OR_UNLATCHED Multiple magazines have been opened or unlatched.

Result code 9081, RC9081, FSC9081

Library will not initialize.

2013-02-25T16:35:39.698,      0.0.0.0.0, 000,   sensor-manager,                 ,  error, 0000, 0000, "getCheckProductIDSN: Base KLM no SN no match in KLC and KLO"
2013-02-25T16:35:39.699,      0.0.0.0.0, 000,   sensor-manager,                 ,  error, 0000, 0000, "SensorMgr - setting library InOp due to Product ID issues!"


Replaced the robot and magazines but did not resolve the issue.

The actual error can be misleading as the problem is related to a serial number issue.

Changes

New install.  Multiple parts replaced on SL150.

Cause

Problem was the original issue being a defective robot module.  Once that was resolved, other parts were swapped causing the problem of loosing the serial number on the SL150.

Base module, KLM, and robotics module have serial number information embedded.  Due to multiple parts being replaced at once.  Valid serial number information was lost.  This prevented the SL150 from intializing and displaying error code 9081.

Solution

This issue was resolved by engineering logging into the SL150 using "Manufacturing" login access and rebuilding the SL150 serial number information.

The issue seems to be a mismatch between serial numbers on the KLC (robot) and the KLO (OP panel).  The unit does not have a serial number in the KLM, and the KLC and KLO SNs
do not match.    It seems that they must have done a base, and a robot or op panel.  They either need to put the original KLM or base back in place to populate the KLC and KLO serial numbers, or find the original bot or op panel and put it in to populate the KLM sn.
------------------------------------------------------

Resolution:
CSE supported the remote operations by engineering via WebEx session.
Via a Webex session, engineering was able to correct the S/N issue.  Once done, the library was able to complete the initialization and fixed the "9081 MAG_MULTIPLE_OPEN_OR_UNLATCHED Multiple magazines have been opened or unlatched" issue.

References

<NOTE:1532502.1> - SL150 - Mail Slot is Not Closing Properly
<NOTE:1509547.1> - SL150 - Firmware Upgrades From Versions Below 1.50 Cannot be Performed Remotely
<NOTE:1471283.1> - SL150 - How To Remove/Replace a Cartridge Magazine CRU In the StorageTek SL150 Modular Tape Library:ATR:1471283.1:0

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback