Created from <SR 3-6892401621> Applies to:Sun StorageTek T10000A Tape Drive - Version Not Applicable to Not Applicable [Release N/A]Sun StorageTek T10000B Tape Drive - Version Not Applicable to Not Applicable [Release N/A] StorageTek T10000C Tape Drive - Version Not Applicable to Not Applicable [Release N/A] Oracle Solaris on SPARC (32-bit) Oracle Solaris on SPARC (64-bit) SymptomsT10000 tape drive attached to Solaris host over (FC) Fibre Channel data path. Faulty tape drive was replaced but post that /dev/rmt/* file is not getting built in OS for the drive in question. Drive is online and green from SLConsole. ============================================ Errors were captured from explorer at the time of problem: ---/var/adm/messages----
--- cfgadm -alv -o show_FCP_dev ------ c18 connected configured unknown unavailable fc-fabric n /devices/pci@500/pci@2/pci@0/pci@a/SUNW,qlc@0/fp@0,0:fc ChangesDrive hardware replacement. CauseIncorrect drive mode selection - FICON/FC SolutionT10K drives support both FICON & FC modes to work with mainframe & open systems respectively. Upon replacement, drive mode was selected as FICON and this prevented Solaris from building device file entries for the replacement drive. Problem was cleared once FE logged into drive via VOP and selected FC mode.