![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1535658.1 : T10000 - Drive/RTD Will Not Vary Online to Server
Created from <SR 3-6908056567> Applies to:Sun StorageTek T10000B Tape Drive - Version Not Applicable to Not Applicable [Release N/A]Sun StorageTek T10000A Tape Drive - Version Not Applicable to Not Applicable [Release N/A] Sun StorageTek Host Software Component (HSC) - Version 7.2 to 7.2 [Release 7.0] Sun StorageTek SL8500 Modular Library System - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. SymptomsCustomer attempts to vary a drive/RTD online in MVS and it fails. Example: %SLS6684I RTD DC2D0B31 ON VTSS DC2D RETURNED ECAM ERROR CC=5 RC=109
%SLS6627E FAILED TO VARY ONLINE RTD DC2D0B31 ON VTSS DC2D
CauseA drive going offline in the backup application may not necessarily mean that the drive is faulty. This status may have been possibly caused by some event on the fiber (data path). Solution1. Look for the drive on SL Console. 2. Reboot the drive on SL Console. This will restart the drive communications. Attachments This solution has no attachment |
||||||||||||
|