Symptoms

  HP-UX server panics with swremove from ATDD driver.

Changes

  Customer applying new ATDD driver on server.

Cause

  HP found panic is caused by ATDD driver used with Oracle sold IBM LTO-4 tape drive.

Solution

  HP_UX 11iv3 panic found by HP to be caused by ATDD driver at version 6.0.2.26.  Customer has upgraded ATDD to current version 6.0.2.27 and it did fix the problem.

 

Link to ATDD:

http://www-933.ibm.com/support/fixcentral/swg/selectFixes?parent=ibm~ST~Tapedevicedriversandsoftware&product=ibm/Storage_Tape/Tape+device+drivers&release=1.0&platform=HPUX&function=all