![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1535445.1 : IBM LTO4 - HP-UX Server Panics with swremove from atdd Driver
Created from <SR 3-6896316301> Applies to:IBM LTO4 Tape Drive - Version All Versions and laterHP 9000 HP-UX 11.0 (32 bit) SymptomsHP-UX server panics with swremove from ATDD driver. ChangesCustomer applying new ATDD driver on server. CauseHP found panic is caused by ATDD driver used with Oracle sold IBM LTO-4 tape drive. SolutionHP_UX 11iv3 panic found by HP to be caused by ATDD driver at version 6.0.2.26. Customer has upgraded ATDD to current version 6.0.2.27 and it did fix the problem.
Link to ATDD: References<NOTE:1306496.1> - HP-UX Server Panics After Reboot to Apply Network ChangesAttachments This solution has no attachment |
||||||||||||
|