Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1534773.1
Update Date:2013-03-21
Keywords:

Solution Type  Problem Resolution Sure

Solution  1534773.1 :   Ops Center 12c Shows Incorrect Suffix For 7320 Appliance  


Related Items
  • SPARC SuperCluster T4-4
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>SPARC SuperCluster>DB: SuperCluster_EST
  •  




Created from <SR 3-6306497541>

Applies to:

SPARC SuperCluster T4-4 - Version All Versions and later
Oracle Solaris on SPARC (64-bit)

Symptoms

Discovery of the embedded 7320 appliance in Ops Center results in an object with inconstant names between the active and passive heads. 

Cause

 Unpublished Bug:15821194 - SUNBT7203459 ZFS ILOM SUFFIX DOESN'T SHOW IN NON-ACTIVE HEAD

which is a duplicate of Unpublished Bug 15789738: SUNBT7166434-12.2.0.0.0 HOSTNAME OF STORAGE & EXADATA CELL COMPONENTS CONTAINS "

Solution

 Latest fix provided in Ops Center in February 2013 has resolved this issue.

References

<BUG:15821194> - SUNBT7203459 ZFS ILOM SUFFEX DOESN'T SHOW IN NON-ACTIVE HEAD

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback