![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1534773.1 : Ops Center 12c Shows Incorrect Suffix For 7320 Appliance
Created from <SR 3-6306497541> Applies to:SPARC SuperCluster T4-4 - Version All Versions and laterOracle Solaris on SPARC (64-bit) SymptomsDiscovery of the embedded 7320 appliance in Ops Center results in an object with inconstant names between the active and passive heads. CauseUnpublished Bug:15821194 - SUNBT7203459 ZFS ILOM SUFFIX DOESN'T SHOW IN NON-ACTIVE HEAD which is a duplicate of Unpublished Bug 15789738: SUNBT7166434-12.2.0.0.0 HOSTNAME OF STORAGE & EXADATA CELL COMPONENTS CONTAINS " SolutionLatest fix provided in Ops Center in February 2013 has resolved this issue. References<BUG:15821194> - SUNBT7203459 ZFS ILOM SUFFEX DOESN'T SHOW IN NON-ACTIVE HEADAttachments This solution has no attachment |
||||||||||||
|