Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1533558.1
Update Date:2017-05-19
Keywords:

Solution Type  Problem Resolution Sure

Solution  1533558.1 :   SL3000 - CEM Upgrade, Not Able to Change the "Active Cell" Count  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-6868855988>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Non Partitioned SL3000 running 3.0 code with HLI-ACSLS interface.
Additional CEM is installed to existing Base and 3 * CEMs.
Hardware Activation Keys were installed and  Library is power cycled.

New slots count is detected but "Active cell" count can not be changed from SLC (Streamline Library Console).

ACSLS can not see the tapes/slots that were detected before upgrade.

Changes

CEM upgrade.

Cause

Code Issue.

Solution

Workaround :

Change "Inteface Type" from HLI to FC/SCSI and apply. Notice the Active Cell count is getting changed.
Then change the Interface back to HLI and apply.

-----Logs REF :
2013-02-28T12:55:01.639 warn 1.0.0.0.0 3811 "Library started - version FRS_3.00 - Active",
2013-02-28T12:54:57.616 info 1.0.0.0.0 3228 "Feature license - License loaded:", FeatureName=Capacity Expiration=noExpiration FeatureValue=2825

Activated Capacity : 2825
Active Cells : 2200 <--------- This value changed to 2731 after workaround.
Total Slot Count : 2731
Empty Slot Count : 745
----------

 

References

@ created a new KB as I could not find old KB which addressed similar issue.
<NOTE:1384090.1> - SL3000 - ACSLS Not Able to Detect New Slot Count

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.