![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1533558.1 : SL3000 - CEM Upgrade, Not Able to Change the "Active Cell" Count
In this Document
Created from <SR 3-6868855988> Applies to:Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsNon Partitioned SL3000 running 3.0 code with HLI-ACSLS interface. New slots count is detected but "Active cell" count can not be changed from SLC (Streamline Library Console). ACSLS can not see the tapes/slots that were detected before upgrade. ChangesCEM upgrade. CauseCode Issue. SolutionWorkaround :
References@ created a new KB as I could not find old KB which addressed similar issue.<NOTE:1384090.1> - SL3000 - ACSLS Not Able to Detect New Slot Count Attachments This solution has no attachment |
||||||||||||||||||||
|