![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1532098.1 : SL150 - New Install, Robot Fails with Error 9109, Robot Initialization Failure
In this Document
Created from <SR 3-6834326453> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform. Symptoms #define LIBMD_ROBOT_INITIALIZATION_FAILURE_FAULT_CODE 9109 //_supported_ RC9109, Result Code 9109 Robot would not drop down properly during initialization. Library has amber light on. Powered it off. Robot failure, there are no tapes in library yet. Robot replacement did not fix this issue. ChangesNew install. CauseFSE found that there's some plastic guide in the back of the expansion module that is loose and causing the suspect obstruction to the robot. SolutionReplaced another DOA robot then the base module chassis to clear the faults. Attachments This solution has no attachment |
||||||||||||||||||
|