Solution  1531798.1 :   Hwmgmtd may report "unexpected SCSI SENSE" event  


Related Items
  • Sun Server X2-8
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Server>SN-x64: SERVER 64bit
  •  




Created from <SR 3-6435062189>

Applies to:

Sun Server X2-8 - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Hwmgmtd may report "unexpected SCSI SENSE" event

Symptoms

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Sun x86 Systems

 

 In some case, after installed OHMP 2.2.3.x, below event may output during system booting.

---log sample---

Nov 12 14:18:31 hostname hwmgmtd[651]: [ID 702911 daemon.notice] Event 44: Component: /SYS/DBP/HDD0, Disk reported unexpected SCSI SENSE data to controller which may indicate a compatibility issue between the controller firmware version and disk model, id=/SYS/DBP/HDD0.

Nov 12 14:18:31 hostname hwmgmtd[651]: [ID 702911 daemon.notice] Event 44: Component: /SYS/DBP/HDD2, Disk reported unexpected SCSI SENSE data to controller which may indicate a compatibility issue between the controller firmware version and disk model, id=/SYS/DBP/HDD2.

Nov 12 14:18:31 hostname hwmgmtd[651]: [ID 702911 daemon.notice] Event 44: Component: /SYS/DBP/HDD4, Disk reported unexpected SCSI SENSE data to controller which may indicate a compatibility issue between the controller firmware version and disk model, id=/SYS/DBP/HDD4.

Nov 12 14:18:31 hostname hwmgmtd[651]: [ID 702911 daemon.notice] Event 44: Component: /SYS/DBP/HDD5, Disk reported unexpected SCSI SENSE data to controller which may indicate a compatibility issue between the controller firmware version and disk model, id=/SYS/DBP/HDD5.

Nov 12 14:18:31 hostname hwmgmtd[651]: [ID 702911 daemon.notice] Event 44: Component: /SYS/DBP/HDD7, Disk reported unexpected SCSI SENSE data to controller which may indicate a compatibility issue between the controller firmware version and disk model, id=/SYS/DBP/HDD7.
---end-----

Changes

 

Cause

The disk drives had been spun down in case there's no IO on them. HMP send
some SCSI commands for disk inventory report, which will trigger some errors,
and spun up the disk drives.


please check below item if no error reported.

- Operating system is not reporting any disk errors.
- RAID HBA shows all physical disks healthy. Zero error counters and SMART data OK.
- RAID HBA shows all the Logical Volumes in Optimal health.

If no warning or error level event logged and just the messages are 'notice' level only. We can safe ignore these messages.

 

Solution

Upgrade HMP to 2.3.0 or higher releases. If messages still output during system booting, open a Hardware Service Request to Support.
Similar Bug 16800787 fixed by HMP 2.3 and higher release.