Asset ID: 1-72-1531240.1
Update Date:2017-05-23
Keywords:

Solution Type  Problem Resolution Sure

Solution  1531240.1 :   SL150 - Issues With Drive 1, LTO Drive and Library Not Being Seen by Switch During Installation of Equipment  


Related Items
  • HP LTO5 Tape Drive
  •  
  • HP LTO6 Tape Drive
  •  
  • StorageTek SL150 Modular Tape Library
  •  
  • HP LTO4 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-6834566813>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
HP LTO4 Tape Drive - Version Not Applicable and later
HP LTO5 Tape Drive - Version Not Applicable and later
HP LTO6 Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

HP LTO-5 Drive and SL150 are not showing up in the switch.
No problem in the console with the drive.

 Drive and Library Not Being Seen by Switch

Changes

 New SL150 installation.

Cause

 Defective Drive.  Shared interface on drive is defective preventing the library and drive to be seen by switch

Solution

Swapped drive 1 and drive 2.

Now drive 2 disappears from switch and media changer and drive 1 are seen on Switch.

Drive 2 will be replaced.


Attachments
This solution has no attachment