![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1531240.1 : SL150 - Issues With Drive 1, LTO Drive and Library Not Being Seen by Switch During Installation of Equipment
In this Document
Created from <SR 3-6834566813> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterHP LTO4 Tape Drive - Version Not Applicable and later HP LTO5 Tape Drive - Version Not Applicable and later HP LTO6 Tape Drive - Version All Versions and later Information in this document applies to any platform. SymptomsHP LTO-5 Drive and SL150 are not showing up in the switch. Drive and Library Not Being Seen by Switch ChangesNew SL150 installation. CauseDefective Drive. Shared interface on drive is defective preventing the library and drive to be seen by switch SolutionSwapped drive 1 and drive 2. Now drive 2 disappears from switch and media changer and drive 1 are seen on Switch. Drive 2 will be replaced. Attachments This solution has no attachment |
||||||||||||||||||
|