![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1528708.1 : Sun Storage 7000 Unified Storage System: After upgrade to 2011.1.5.0, cannot connect to BUI (connect to CLI successful)
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun ZFS Storage 7420 - Version All Versions to Not Applicable [Release All Releases to N/A]Sun ZFS Storage 7320 - Version All Versions to Not Applicable [Release All Releases to N/A] Sun ZFS Storage 7120 - Version All Versions to Not Applicable [Release All Releases to N/A] Sun Storage 7410 Unified Storage System - Version All Versions to Not Applicable [Release All Releases to N/A] Sun Storage 7310 Unified Storage System - Version All Versions to Not Applicable [Release All Releases to N/A] Information in this document applies to any platform. SymptomsAfter upgrading controller to 2011.1.5.0 (ak-2011.04.24.5.0), customer could connect to the CLI but he could not connect through BUI. Cause ......... SolutionReset the port providing in BUI connection (215). # svccfg -s svc:/appliance/kit/akd setprop akd/https_port=215
Attachments This solution has no attachment |
||||||||||||||||
|