Solution Type  Problem Resolution Sure

Solution  1528026.1 :   SL3000 - Drive 1,1,1,1,1 Is Non-functional, No Power on Drive  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-6500689461>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

Drive 1.1.1.1.1 is non functional

Drive_Bay4(1.1.1.1.1)

1301 - (1X)
Device response time-out, request= controlPower Internal 1,1,1,1,1 on address = Drive_Bay4(1,1,1,1,1)
(Errors Started - 2012-11-28 11:54:46 Errors Stopped - 2012-11-28 11:54:46)

1303 - (1X)
Failure from drive Code: 604 - Drive is not functional, Power on failed for drivetray
(Errors Started - 2012-11-29 10:25:10 Errors Stopped - 2012-11-29 10:25:10)

1320 - (1X)
Drive communication time-out - drive - powerState ,
(Errors Started - 2012-11-28 11:54:46 Errors Stopped - 2012-11-28 11:54:46)

3955 - (1X)
Error from device Code: 604 - Drive is not functional, Power on failed for drivetray
(Errors Started - 2012-11-29 10:25:10 Errors Stopped - 2012-11-29 10:25:10)

3994 - (3X)
Device removed, device=drive
(Errors Started - 2012-11-28 11:42:51 Errors Stopped - 2012-11-29 10:25:32)

Cause

Power on failed for drive tray.
 

Solution

The PS of the tray from drive 1.1.1.1.1 is HS, need replacement.

Part number: 314344601
Description: PS,DC/DC,+5V,+12V,95W (FRU)