Asset ID: |
1-72-1528026.1 |
Update Date: | 2017-08-08 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1528026.1
:
SL3000 - Drive 1,1,1,1,1 Is Non-functional, No Power on Drive
Related Items |
- Sun StorageTek SL3000 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Created from <SR 3-6500689461>
Applies to:
Sun StorageTek SL3000 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.
Symptoms
Drive 1.1.1.1.1 is non functional
Drive_Bay4(1.1.1.1.1)
1301 - (1X)
Device response time-out, request= controlPower Internal 1,1,1,1,1 on address = Drive_Bay4(1,1,1,1,1)
(Errors Started - 2012-11-28 11:54:46 Errors Stopped - 2012-11-28 11:54:46)
1303 - (1X)
Failure from drive Code: 604 - Drive is not functional, Power on failed for drivetray
(Errors Started - 2012-11-29 10:25:10 Errors Stopped - 2012-11-29 10:25:10)
1320 - (1X)
Drive communication time-out - drive - powerState ,
(Errors Started - 2012-11-28 11:54:46 Errors Stopped - 2012-11-28 11:54:46)
3955 - (1X)
Error from device Code: 604 - Drive is not functional, Power on failed for drivetray
(Errors Started - 2012-11-29 10:25:10 Errors Stopped - 2012-11-29 10:25:10)
3994 - (3X)
Device removed, device=drive
(Errors Started - 2012-11-28 11:42:51 Errors Stopped - 2012-11-29 10:25:32)
Cause
Power on failed for drive tray.
Solution
The PS of the tray from drive 1.1.1.1.1 is HS, need replacement.
Part number: 314344601
Description: PS,DC/DC,+5V,+12V,95W (FRU)
Attachments
This solution has no attachment