1527945.1
:
SL8500 - Complete Power Failure Of Library
Related Items |
- Sun StorageTek SL8500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential to Service Personnel Only
Created from <SR 3-6534346751>
Applies to:
Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.
Symptoms
Our SL8500 is experiencing a complete power failure. If we try to power on the system through the main power supply switch, the switch immediately turns off again. Both (redundant I imagine) power supplies behave in the same way. So we are not able to power on the system. Our electricians have veryfied that input power is available though. We have for testing purposes turned off all accessible power supplies inside the system prior to switching on the main power supplies without success though.
2012-12-07 21:11:03
Power_Supply_ECM_PS1_AC1(1.0.0.1.27)
1321 - (6X)
Failure from power supplyAddress: 1, 0,0,1,27 - Status:
(Errors Started - 2012-12-07 20:22:19 Errors Stopped - 2012-12-07 21:11:03)
2012-12-07 21:11:03
Power_Supply_Rail_AC1(1.0.0.1.5)
1321 - (8X)
Failure from power supplyAddress: 1, 0,0,1,5 - Status:
(Errors Started - 2012-12-04 13:01:05 Errors Stopped - 2012-12-07 21:11:03)
2012-12-07 21:11:03
Power_Supply_HBZ_25(1.0.0.1.25)
1321 - (7X)
Failure from power supplyAddress: 1, 0,0,1,25 - Status:
(Errors Started - 2012-12-04 13:01:11 Errors Stopped - 2012-12-07 21:11:03)
2012-12-07 21:04:57
Power_Supply_Rail_AC2(1.0.0.1.24)
1321 - (3X)
Failure from power supplyAddress: 1, 0,0,1,24 - Status:
(Errors Started - 2012-12-04 13:01:05 Errors Stopped - 2012-12-07 21:04:57)
2012-12-07 21:04:57
Power_Supply_HBZ_26(1.0.0.1.26)
1321 - (3X)
Failure from power supplyAddress: 1, 0,0,1,26 - Status:
(Errors Started - 2012-12-04 13:01:13 Errors Stopped - 2012-12-07 21:04:57)
2012-12-07 21:04:56
Power_Supply_Rail_AC2(1.0.0.1.23)
1321 - (3X)
Failure from power supplyAddress: 1, 0,0,1,23 - Status:
(Errors Started - 2012-12-04 13:01:05 Errors Stopped - 2012-12-07 21:04:56)
2012-12-07 20:52:02
Power_Supply_Rail_AC1(1.0.0.1.6)
1321 - (8X)
Failure from power supplyAddress: 1, 0,0,1,6 - Status:
(Errors Started - 2012-12-04 13:01:05 Errors Stopped - 2012-12-07 20:52:02)
2012-12-07 20:52:01
Power_Supply_PDU1_AC1(1.0.0.1.29)
1321 - (3X)
Failure from power supplyAddress: 1, 0,0,1,29 - Status:
(Errors Started - 2012-12-07 20:49:35 Errors Stopped - 2012-12-07 20:52:01)
Cause
Customer already did the technical diagnostics: seems to be a power supply issue.
Solution
Replaced PDU, (Power Distribution Unit).