![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1527929.1 : SL8500 - Error: 0708 - LSM Robotics Error: Failed Robotics Portion Of MOVE
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL8500 Modular Library System - Version All Versions and laterInformation in this document applies to any platform. Symptoms2012-11-29 06:57:28 ACSLH[0]: RC5416, 5416 CauseDefective PTP. SolutionLeft bot on the rail which fails consistently with a targeting error_5416. The targeting is successful with the 2nd bot on the rail. This is due to a marginal track alignment problem which requires a special tool to check/adjust. misalignment in Lib2 and PTP frames between library 2 and library 3. Replaced defective PTP module. How to Remove / Replace the Pass-Thru Port ( PTP ) Mechanism in SL8500 Library:ATR:1368301.1:2 (Doc ID 1368301.1) References<NOTE:1384809.1> - SL8500/SL3000 - How to Troubleshoot "Servo Mech Reach" Events<NOTE:1368301.1> - How to Remove / Replace the Pass-Thru Port ( PTP ) Mechanism in SL8500 Library:ATR:1368301.1:2 <NOTE:1306050.1> - SL8500 - Troubleshooting Pass-Thru-Port (PTP) Failure Attachments This solution has no attachment |
||||||||||||||||||
|