Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1527929.1
Update Date:2017-09-25
Keywords:

Solution Type  Problem Resolution Sure

Solution  1527929.1 :   SL8500 - Error: 0708 - LSM Robotics Error: Failed Robotics Portion Of MOVE  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential to Service Personnel Only
Created from <SR 3-6502112641>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

2012-11-29 06:57:28 ACSLH[0]:
2378 N Co_ProcessResponses.C 1 1394
ACS: 1; LC/LMU error: Co_4400:st_parse_error:
Error: 0708 - LSM robotics error: Failed robotics portion of MOVE
Request: Mount

RC5416, 5416

Cause

Defective PTP.
 
Misalignment in Library 2 and PTP (Pass-Thru-Port) frames between library 2 and library 3.
 

Solution

Left bot on the rail which fails consistently with a targeting error_5416. The targeting is successful with the 2nd bot on the rail.  This is due to a marginal track alignment problem which requires a special tool to check/adjust. misalignment in Lib2 and PTP frames between library 2 and library 3.

Replaced defective PTP module.

How to Remove / Replace the Pass-Thru Port ( PTP ) Mechanism in SL8500 Library:ATR:1368301.1:2 (Doc ID 1368301.1)
 

References

<NOTE:1384809.1> - SL8500/SL3000 - How to Troubleshoot "Servo Mech Reach" Events
<NOTE:1368301.1> - How to Remove / Replace the Pass-Thru Port ( PTP ) Mechanism in SL8500 Library:ATR:1368301.1:2
<NOTE:1306050.1> - SL8500 - Troubleshooting Pass-Thru-Port (PTP) Failure