![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1527309.1 : T10000 - T10KA and T10KB Drives Reporting Tape Errors Since Firmware Upgrade to 1.48.x12
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek T10000B Tape Drive - Version Not Applicable to Not Applicable [Release N/A]Sun StorageTek T10000A Tape Drive - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. SymptomsDrive reporting FSC 34B8, 349C, 3002, and 31E8 FSC34B8, FSC349C, FSC3002, FSC31E8 ChangesAfter upgrading drive from 1.48.205 to 1.48.212 . CauseCode bug from 1.48.x12. SolutionRequest RA.48.x12 (special code) from Level 2 support. This fix will be incorporated into the next version of released firmware. Attachments This solution has no attachment |
||||||||||||||||||
|