Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1527309.1
Update Date:2017-09-20
Keywords:

Solution Type  Problem Resolution Sure

Solution  1527309.1 :   T10000 - T10KA and T10KB Drives Reporting Tape Errors Since Firmware Upgrade to 1.48.x12  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: code fix
Created from <SR 3-6780532309>

Applies to:

Sun StorageTek T10000B Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Sun StorageTek T10000A Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

Drive reporting FSC 34B8, 349C, 3002, and 31E8

FSC34B8, FSC349C, FSC3002, FSC31E8

Changes

  After upgrading drive from 1.48.205 to 1.48.212 .

Cause

Code bug from 1.48.x12.

 

Solution

Request RA.48.x12 (special code) from Level 2 support.  This fix will be incorporated into the next version of released firmware.
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback