Solution Type Problem Resolution Sure Solution 1526891.1 : F20 card not seen in a storage server at the ILOM level
In this Document
Created from <SR 3-6768074938> Applies to:Exadata Database Machine X2-2 Half Rack - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsStorage server has an issue “Electronic Storage Module (ESM) Lifetime is not within specification for one or more flash cards on one or more storage servers” ChangesNo Changes Cause===> Faulty: PCI RISER CARD The ILOM shows PCIE2/F20CARD missing: Solution1. Reset the ILOM to see if this brings back the aura card data - check to see if problem is resolved. 2. If step #1 fails, power cycle the system so that everything gets reinitialized including the riser - check to see if problem is resolved. 3. If step #2 fails, engage HW team to dispatch an FE who can reseat the Riser card - check to see if problem is resolved. 4. Lastly, if all previous steps have failed, replace the PCI RISER Card. Attachments This solution has no attachment |
||||||||||||||||||
|