Solution Type  Problem Resolution Sure

Solution  1526891.1 :   F20 card not seen in a storage server at the ILOM level  


Related Items
  • Exadata Database Machine X2-2 Half Rack
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-6768074938>

Applies to:

Exadata Database Machine X2-2 Half Rack - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Storage server has an issue “Electronic Storage Module (ESM) Lifetime is not within specification for one or more flash cards on one or more storage servers”

reported by EXACHK 2.2.0.

-> show /SYS/MB/RISER2/PCIE2/F20CARD

show: Invalid target /SYS/MB/RISER2/PCIE2/F20CARD

All the flash disks are present and seem correctly setup.

Changes

 No Changes

Cause

===> Faulty: PCI RISER CARD

The ILOM shows PCIE2/F20CARD missing:

FRU Device Description : PCIE1/F20CARD (LUN 0, ID 225)
Board Product         : ASY,BD,PCIE_FLASH,F20 M2
Board Serial          : 465769T+1219A414VU
Board Part Number     : 511-1646-03
Board Extra           : 02
Board Extra           : F20 M2

FRU Device Description : PCIE2/F20CARD (LUN 0, ID 226)
Device not present (Requested sensor, data, or record not found)            <<<<<<<<<<<<<<

FRU Device Description : PCIE4/F20CARD (LUN 0, ID 228)
Board Product         : ASY,BD,PCIE_FLASH,F20 M2
Board Serial          : 465769T+1219A414VL
Board Part Number     : 511-1646-03
Board Extra           : 02
Board Extra           : F20 M2

FRU Device Description : PCIE5/F20CARD (LUN 0, ID 229)
Board Product         : ASY,BD,PCIE_FLASH,F20 M2
Board Serial          : 465769T+1220A416XD
Board Part Number     : 511-1646-03
Board Extra           : 02
Board Extra           : F20 M2

Solution

1. Reset the ILOM to see if this brings back the aura card data - check to see if problem is resolved.

2. If step #1 fails, power cycle the system so that everything gets reinitialized including the riser - check to see if problem is resolved.

3. If step #2 fails, engage HW team to dispatch an FE who can reseat the Riser card - check to see if problem is resolved.

4. Lastly, if all previous steps have failed, replace the PCI RISER Card.