Solution Type  Problem Resolution Sure

Solution  1522313.1 :   72P Switch: Not Able To Select/restrict Vlans on A Trunk Port (all Are Trunked)  


Related Items
  • Sun Network Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Ethernet Switches
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-6477137287>

Applies to:

Sun Network Switch - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

 Not able to select/restrict which vlans are trunked on a trunk port with pvst+  (all are trunked) on Network 10Gigabit Ethernet Switch 72p
and 24-Port 10-Gigabit Ethernet Switched Network Express Module switches.

 

Cause

In the current firmware release 1.2.1.8  VLAN pruning is not supported when PVST is enabled.

Solution

 Development will include this feature in a future release.