Solution Type
Problem Resolution Sure
Solution
1520576.1
:
Running ./ibswitchcheck.sh post on a leaf switch falsely reports spine switch
Related Items |
- Sun Datacenter InfiniBand Switch 36
- Exadata Database Machine X2-2 Full Rack
|
Related Categories |
- PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Infiniband
|
In this Document
Applies to:
Sun Datacenter InfiniBand Switch 36 - Version Not Applicable to Not Applicable [Release N/A]
Exadata Database Machine X2-2 Full Rack - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
Running ibswitchcheck.sh post on a leaf switch falsley reports the switch as a spine
[root@ib2 tmp]# ./ibswitchcheck.sh post
Current version of switch is: 1.3.3-2 and is a spine <<<<-----------------------
Switch target version is: 1.3.3-2
[SUCCESS] Switch is at target patching level
[SUCCESS] Hostname ora2sw-ib2.central.hq.internal passed validation
in /etc/hosts and /etc/sysconfig/network-scripts/ifcfg-eth0
[SUCCESS] Service ntpd is running
[ERROR] Service opensmd is not running
Action: Start opensm service by issuing 'enablesm'
[SUCCESS] Number of ntp servers 2 meets minimal requirement of 1
ntp server: 12.12.1.0
ntp server: 10.25.21.232
[ERROR] opensm.conf failed all or some of the validation
[SUCCESS] routing_engine value in /etc/opensm/opensm.conf is ftree
[SUCCESS] controlled_handover value in /etc/opensm/opensm.conf is TRUE
[SUCCESS] sminfo_polling_timeout value in /etc/opensm/opensm.conf is
1000
[SUCCESS] polling_retry_number value in /etc/opensm/opensm.conf is 5
[ERROR] sm_priority must equal 8, value in /etc/opensm/opensm.conf is 5
Action: issue disablesm, set priority using 'setsmpriority 8', issue
enablesm
Manually validate the following entries
Date:(MM/DD/YY) 01/16/13
Time:(HH:MM:SS) 13:10:29
Timezone: EST
[SUCCESS] /conf/configvalid is 1
Overall status of post check is ERROR
Cause
The script wrongly reports that this is a spine switch if there are NO hosts/nodes on the fabric.
If the ib fabric is not up or the cables are not connected you may see the ERROR above.
Solution
Ignore the error message if the fabric is not up or if the nodes/hosts are not UP on the IB fabric.
Insure that at least some of the nodes are up on the network before running the script.