![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1519083.1 : Sun Storage Common Array Manager (CAM) Returns the Alarm with Event Code 93.66.9999 and Fault ID 434 for a Sun Storage 2500-M2 Array
In this Document
Applies to:Sun Storage Common Array Manager (CAM) - Version 6.0 to 6.9 [Release 6.0]Sun Storage 2530-M2 Array - Version Not Applicable and later Sun Storage 2540-M2 Array - Version Not Applicable and later Information in this document applies to any platform. SymptomsAfter resetting an array configuration using either the following CAM command line (CLI): sscs reset -l array array <arrayname>
/* `sscs` is under:
/* Solaris: /opt/SUNWstkcam/bin/ /* Linux: /opt/sun/cam/bin/ /* Windows: C:\Program Files\Sun\Common Array Manager\bin Storage Systems -> <arrayname> -> Administration -> Reset Configuration… -> Reset Storage Array Configuration CAM raises the following alarm: Alarm Id : alarm83
Severity : Major Type : 2540m2.ProblemEvent Topic : unlabeled Event Code : 93.66.9999 Date : 2013-01-11 12:57:32 Device : unlabeled[SUN.7010610.hidden] Description : The array has reported an undefined fault. Fault ID: 434. State : Open Acknowledged By : - Auto Clear : Y Aggregated Count : 0
Note: It takes 5 minutes for CAM to raise the alarm. This is the default polling interval.
ChangesThe conditions to encounter this situation are:
CauseThe fault ID 434 means that the controller is booting up in database recovery mode, with no configuration. The backup database images are locked in read-only mode. The storage administrator is expected to recreate the configuration, using the database backup images.
Solution
Note: CAM 6.10 is currently only available for Solaris SPARC and x86, if you are not in position to upgrade to CAM 6.10, you need to contact Oracle Support so that an engineer can provide instructions to resolve this error.
Internal Only Note: This is the procedure to follow if the customer cannot upgrade to CAM 6.10 which includes the solution for this problem.
For TSC L2 engineers:
References<BUG:16104490> - NEED TO IMPLEMENT THE CLI "CANCELDATABASERECOVERYMODE" IN CAM<BUG:16103441> - RESETING ARRAY CONFIGURATION FROM CAM PUTS THE CONTROLLERS IN RECOVERY MODE Attachments This solution has no attachment |
||||||||||||||||||||
|