![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1518881.1 : Recognizing and Troubleshooting an Incomplete System Service Processor (SP) Firmware Upgrade on T2000 Series
This document will provide guidance on Recognizing and Troubleshooting an Incomplete System Service Processor (SP) Firmware-Upgrade on T2000 systems that have a plug-in System Service Processor. *** Please note that this component has become widely known under different names, such as: System Service Processor (SSP), System Controller (SC), ALOM Card (ALOM). In this Document
Created from <SR 3-6651723690> Applies to:Sun Fire T2000 Server - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsPrior to attempting the installation of new Firmware Binary, issuing the "showhost" ALOM command will provide a view of the currently installed system firmware: sc> showhost
Sun-Fire-T2000 System Firmware 6.5.11 2008/01/08 20:24 <--- Old Values prior to FW update Host flash versions: Hypervisor 1.3.4 2007/03/28 06:03 <--- Old Values OBP 4.25.12 2008/03/23 13:27 <--- Old Values POST 4.25.12 2008/03/23 13:52 <--- Old Values sc> flashupdate -s 1XX.1XX.X.XX -f /home/PATCHES/139434-09/Sun_System_Firmware-6_X_X2-Sun_Fire_T2000.bin
Username: admin Password: ********* flashupdate: validating image... Programming ALOM flash. Erasing segment 0 Programming segment 0 Erasing segment 1 Programming segment 1 Erasing segment 2 Programming segment 2 Erasing segment 3 Programming segment 3 Erasing segment 4 ~SNIP~ Programming segment 3d Erasing segment 3e Programming segment 3e Erasing segment 3f Programming segment 3f Validating flash image crc..............ALOM was programmed successfully. Error programming OBP segment into flash
Error updating software. sc> showhost
Sun-Fire-T2000 System Firmware 6.7.12 2011/07/06 20:03 <--- New Value Host flash versions: Hypervisor 1.3.4 2007/03/28 06:03 <--- Old Values OBP 4.25.12 2008/03/23 13:27 <--- Old Values POST 4.25.12 2008/03/23 13:52 <--- Old Values sc> showhost
Sun-Fire-T2000 System Firmware 6.7.12 2011/07/06 20:03 <--- NEW Values Host flash versions: Hypervisor 1.7.3.c 2010/07/09 15:14 <--- NEW Values OBP 4.30.4.b 2010/07/09 13:48 <--- NEW Values POST 4.30.4.b 2010/07/09 14:24 <--- NEW Values
CauseThe cause for this issue has been determined as any of the following: SolutionPlease follow these 4 steps, in order: 3- If the issue still remains, unplug power from the machine and re-seat the SSP card, then repeat the firmware update procedure once more. (Please refer to the following documentation on proper SP Card handling: Service Manual or relevant portion in 1308278.1 ) References<NOTE:1004230.1> - Troubleshooting Firmware Upgrade Issues on a T1000/T2000Attachments This solution has no attachment |
||||||||||||||||||
|