![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1518775.1 : Exadata: Flash Disks Reported as "NOT PRESENT" then Returns to "NORMAL" State without User Intervention
Created from <SR 3-6616234271> Applies to:Exadata Database Machine X2-2 Full Rack - Version All Versions and laterOracle Exadata Hardware - Version 11.2.0.1 and later Information in this document applies to any platform. Image versions: 11.2.2.4.2 or earlier Symptoms
The alert however automatically clears itself after a short time and returns to "Normal" status. For example: here is a sample output from alert history:
4_1 2012-12-31T17:23:06-05:00 critical "Flash disk removed. Status : NOT PRESENT Manufacturer : MARVELL Model Number : SD88SA02 Size : 23G Serial Number : 1146M0ALJ8 Firmware : D20Y Slot Number : PCI Slot: 1; FDOM: 0 Cell Disk : FD_00_xdhfd6st12 Grid Disk : No grid disks exist Flash Cache : Present Flash Log : Present Error Count : 0 Last Failure : unknown"
4_2 2012-12-31T17:27:26-05:00 clear "Flash disk replaced. Status : NORMAL Manufacturer : MARVELL Model Number : SD88SA02 Size : 23G Serial Number : 1146M0ALJ8 Firmware : D20Y Slot Number : PCI Slot: 1; FDOM: 0 Cell Disk : FD_00_xdhfd6st12 Grid Disk : No grid disks exist Flash Cache : Present Flash Log : Present" CauseThis is <Bug 13486258>: MULTIPLE ALERTS RELATED TO FLASH CARDS REPORTED FEW SECONDS APART. You are hitting this bug if the flash disks are reported as "NOT PRESENT" and flips back to "NORMAL" status automatically without any user intervention. Solution
References<BUG:13486258> - MULTIPLE ALERTS RELATED TO FLASH CARDS REPORTED FEW SECONDS APPARTAttachments This solution has no attachment |
||||||||||||
|