Solution Type Problem Resolution Sure Solution 1517720.1 : SL150 - Rackmount Kit Screw Is Broken Off Inside Mounting Block
Installation problem can accrue if wrong screws used on mounting block on back rail. carefully read and follow instructions in SL150 Library System installation Manual Document Number E28647-01 date March 2012 or later Hardware Installation chapter reference the 'back rail' ( Part No.7010304 (RACK MOUNTING BLOCK) & Part No. 10207504 (SCR MATCH, 8-32X5/8) . In this Document
Created from <SR 3-6635302321> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform. SymptomsScrew can shear off inside the mounting block for the back rail, if the wrong screw is used and or if correct screw or wrong screw used is over tightened. ChangesThis is a new installation of SL150 library. CauseIf attempting to mount the Block with a 10-32x5/8 screw, the screw will resist about half way in, and if you attempt to force or over tighten it, the screw will shear off . Only use the 8-32x5/8 screws and 'DO NOT OVER TIGHTEN' the screw. SolutionHardware Installation references the 'back rail' ( Part No.7010304 (RACK MOUNTING BLOCK) & Part No. 10207504 (SCR MATCH, 8-32X5/8) . The Back Rail is installed at the rear of the rack. Installation is of 3 parts: 1- back rail 2- mounting block 3- Quantity -1, 8-32x5/8 screw (currently shown in figure 3-5 on page 30 of Install Manual , Document Number E28647-01, date March 2012 or later) Attachments This solution has no attachment |
||||||||||||||||||
|