Solution Type Problem Resolution Sure Solution 1514931.1 : T10000B - File Protected With Multiple Cartridges (Code level : 1.48.205)
In this Document
Created from <SR 3-6374907518> Applies to:Sun StorageTek T10000B Tape Drive - Version Not Applicable and laterInformation in this document applies to any platform. SymptomsT10K drive (0CD4) 1,2,-1,1,1 (serial:572004012107) -spares tapes freeze as write protected. Multiple carts went to file protected (Ready_F) with single drive. FSC3D50, FSC3D53 CauseDrive would set write protect to prevent writing by quality degraded drive with 1.48.205 code level. According to CR_7129863, in the next code release we will generate a write perm when writes of customer data are attempted. A new FSC was added that explains the problem and suggested a corrective action. SolutionReplace the drive. Attachments This solution has no attachment |
||||||||||||||||
|