![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1514870.1 : SL8500 - Operator Panel Shows Incorrect Tape Drive Information
In this Document
Created from <SR 3-6352951309> Applies to:Sun StorageTek SL8500 Modular Library System - Version Not Applicable and laterInformation in this document applies to any platform. SymptomsSLConsole shows incorrect drive tree. Missing 2 drives from SL8500 SLConsole drive tree (1,3,2,1,3 / 1,3,2,1,4). Existing 2 drives (1,3,2,1,3/1,3,2,1,4) are not shown in left drive tree even though shown in right drive folder on local panel. CauseUnsupported SLC version is installed. SolutionReturned correct drive tree after refreshing screen. Actual installed code information as reported by local team Upgrade to latest SLConsole level firmware. Attachments This solution has no attachment |
||||||||||||||||
|