Asset ID: |
1-72-1514868.1 |
Update Date: | 2017-05-22 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1514868.1
:
SL500 - RC8003, RC8013, RC8023 at 3rd Module (DEM)
Related Items |
- Sun StorageTek SL500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
|
In this Document
Created from <SR 3-6026654281>
Applies to:
Sun StorageTek SL500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Symptoms
SL500 Primary and secondary powers for 3rd module (DEM) went to inop (RC_8003) and All 4 drives shown unusual states (RC_8013/8023).
SL500/ PS LED Off
Logged events are:
RC_8003
"SensorPowerFuncs: doPwrSupplyState - Module 3 Power Supply 1 is not operational"
"SensorPowerFuncs: doPwrSupplyState - Module 3 Power Supply 2 is not operational"
RC_8023 "SensorDriveFuncs:handleDrvTempChanges - Module 3 Drive 1 temperature 238 - SEVERE threshold of 99 hit" "SensorDriveFuncs:handleDrvTempChanges - Module 3 Drive 2 temperature 238 - SEVERE threshold of 99 hit" "SensorDriveFuncs:handleDrvTempChanges - Module 3 Drive 3 temperature 236 - SEVERE threshold of 99 hit" "SensorDriveFuncs:handleDrvTempChanges - Module 3 Drive 4 temperature 235 - SEVERE threshold of 99 hit" RC_8013
"SensorDriveFuncs: doDriveFanStatus - Module 3 Drive 1 fan failure"
"SensorDriveFuncs: doDriveFanStatus - Module 3 Drive 2 fan failure" "SensorDriveFuncs: doDriveFanStatus - Module 3 Drive 3 fan failure" "SensorDriveFuncs: doDriveFanStatus - Module 3 Drive 4 fan failure"
RC8003, RC8023, 8003, 8023
Cause
Defective RLE
Solution
Fixed after replacing RLE in 3rd module (DEM).
Attachments
This solution has no attachment