Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1514868.1
Update Date:2017-05-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  1514868.1 :   SL500 - RC8003, RC8013, RC8023 at 3rd Module (DEM)  


Related Items
  • Sun StorageTek SL500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-6026654281>

Applies to:

Sun StorageTek SL500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

SL500 Primary and secondary powers for 3rd module (DEM) went to inop (RC_8003) and All 4 drives shown unusual states (RC_8013/8023).

SL500/ PS LED Off

Logged events are:
RC_8003
"SensorPowerFuncs: doPwrSupplyState - Module 3 Power Supply 1 is not operational"
"SensorPowerFuncs: doPwrSupplyState - Module 3 Power Supply 2 is not operational"
RC_8023 "SensorDriveFuncs:handleDrvTempChanges - Module 3 Drive 1 temperature 238 - SEVERE threshold of 99 hit" "SensorDriveFuncs:handleDrvTempChanges - Module 3 Drive 2 temperature 238 - SEVERE threshold of 99 hit" "SensorDriveFuncs:handleDrvTempChanges - Module 3 Drive 3 temperature 236 - SEVERE threshold of 99 hit" "SensorDriveFuncs:handleDrvTempChanges - Module 3 Drive 4 temperature 235 - SEVERE threshold of 99 hit" RC_8013
"SensorDriveFuncs: doDriveFanStatus - Module 3 Drive 1 fan failure"
"SensorDriveFuncs: doDriveFanStatus - Module 3 Drive 2 fan failure" "SensorDriveFuncs: doDriveFanStatus - Module 3 Drive 3 fan failure" "SensorDriveFuncs: doDriveFanStatus - Module 3 Drive 4 fan failure"

RC8003, RC8023, 8003, 8023


Cause

Defective RLE
 

Solution

Fixed after replacing RLE in 3rd module (DEM).


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.