Solution  1512739.1 :   OEM 12C: Exadata DBM discovery fails with "Failed to launch process: java.net.UnknownHostException" for an Infiniband Switch  


Related Items
  • Exadata Database Machine X2-2 Full Rack
  •  
  • Enterprise Manager for Exadata
  •  
  • Oracle Exadata Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  




Created from <SR 3-6500244211>

Applies to:

Exadata Database Machine X2-2 Full Rack - Version All Versions and later
Enterprise Manager for Exadata - Version 12.1.0.1.0 and later
Oracle Exadata Hardware - Version 11.2.0.1 and later
Information in this document applies to any platform.
OEM 12c: Exadata Database Machine Discovery

Symptoms

 

Discovery fails with java.net.UnknownHostException error in a pop-up message, as shown below:

 

 

Pop up error message

 

 

You can see this is referring to the Infiniband Switch.

 

Cause

The hostname set for the Infiniband switch does not match the configuration files.  Check the following:

 

1.  Check the entry for the switch in "/opt/ oracle.SupportTools/onecommand/databasemachine.xml" where it shows the name as lpnoe02asw-ib3


<ITEM ID="16">
<TYPE>ib</TYPE>
<ADMINNAME>lpone02asw-ib3</ADMINNAME>       <<<<<<<<
<ADMINIP>XXX.XX.XX.XXX</ADMINIP>
<ULOCATION>24</ULOCATION>
<UHEIGHT>1</UHEIGHT>
</ITEM>

 

2.  Check the "hostname" command when connected to the switch; it shows a name mismatch compared with the name specified in "databasemachine.xml":

[root@lpone02asw-ib3 ~]# hostname
lpone02asw-ib3.******.com

 

3.  The ibnetdiscover output also shows the same mismatch:

switchguid=0x212****66a0a0(212****6a0a0)
Switch 36 "S-002****a0a0" # "SUN DCS 36P QDR lpone02asw-ib3.************.com" enhanced port 0 lid 1 lmc 0 

 

 

 

Solution

Correct the hostname of the switch to match the name specified in "/opt/ oracle.SupportTools/onecommand/databasemachine.xml" and continue with discovery

 

Review How To Change Host Name On Infiniband Switches (<Document 1464355.1>) for detailed steps to correct the hostname of an IB switch.