![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1512188.1 : SPARC T3-1 wont boot due to FATAL ERROR:" FATAL: millbrook_inband_read: Timed out waiting for config read to succeed to Node0.MCU1.BoB2.Dev0.Func1.Reg0xe9.[CPU 0:0:0] Fatal configuration error - forcing power-down"
[CPU 0:0:0] FATAL: millbrook_inband_read: Timed out waiting for config read to succeed to Node0.MCU1.BoB2.Dev0.Func1.Reg0xe9.[CPU 0:0:0] Fatal configuration error - forcing power-down In this Document
Created from <SR 3-6491455677> Applies to:SPARC T3-1 - Version Not Applicable to Not Applicable [Release N/A]SPARC SymptomsSPARC T3-1 not bootable due to Fatal error when testing memory link during POST. "Fatal configuration error - forcing power-down" during initialization of the SMI channels during POST: . . CauseMemory test routine may fail sometimes during POST which will prevent the system from booting. SolutionSunPatch:145665-03; FW 8.0.4.c (or later) References<BUG:15662119> - SUNBT6970989-1.0.0 IBIST FIXUP, AND LOWER CONFIG ACCESS LIMIT DURING CHECK_SMI_L<BUG:15657502> - SUNBT6970989-1.0.X IBIST FIXUP, AND LOWER CONFIG ACCESS LIMIT DURING CHECK_SMI_L Attachments This solution has no attachment |
||||||||||||||||||
|