Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1508789.1
Update Date:2017-05-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  1508789.1 :   SL8500 - 3295: "Remote Connection Pool Poll Timeout. Connections In-use/Max: 0/100", LibraryAddress=ILC1 Messages issued to Error Warn Information logs  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  


Following message issued to the SL8500 Error , Warning and Information log. This also triggers ASR alerts.

3295: "Remote Connection Pool Poll Timeout. Connections In-use/Max: 0/100", LibraryAddress=ILC1

In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-6483216978>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
7.70 Firmware
EWI logs

Symptoms

The following appears intermittently in the SL8500 logs (SLC).

3295: "Remote connection pool poll timeout. Connections In-use/Max: 0/100", libraryAddress=ILC1


and in ASR alerts as ...

Hostname:
Product Type: SL8500
Summary:3295: "Remote connection pool poll timeout. Connections In-use/Max: 0/100", libraryAddress=ILC1;

3295: "Remote connection pool poll timeout. Connections In-use/Max: 0/100", libr
Full Description:3295: "Remote connection pool poll timeout. Connections In-use/Max: 0/100", libraryAddress=ILC1;
SdpIncidentId: 18848492
Events -------------------------3295 (Critical): "Remote connection pool poll timeout. Connections In-use/Max: 0/100", libraryAddress=ILC1

Summary Data --------------------
Category: 1 critical event(s) found
Last Known Status: Online
Alert time stamp : 2012-11-22_17-12-09-797
Site unit Local Time : Nov 22, 2012 5:19:17 PM
Site unit GMT Time: Nov 23, 2012 12:19:17 AM
Tracking Serial Number: 516000101081
Device Serial Number: 516000101081
Family Code: SL8500
Type: SL-SERIES
Model: SL8500
Firmware Level: FRS_7.70
Location:
Site ID: xxxx

Changes

 None

Cause

In a multi-library complex this message could be an indication that the ILC is attempting to talk to other SL8500 libraries in the string and timing out.  This might be related to the presence on older sl8500s of the 3COM switch, which is known to start failing little by little or suddenly, bringing the whole library operations down.  A couple of these alerts in the library may lead to a suspicious switch, which is to be replaced by a PUE.

See also:
Article ID 1484207.1  SL8500 - Internal Ethernet 3Com Lan Switch or ILC 3Com Switch Does Not Power Up After Being Powered Down or Intermittent Communication Errors With Various Components in Library
Article ID 1472641.1  SL8500 - 3-Comm Switch Failure, PUE Replacement
Article ID 1293137.1  SL8500 - IP Switch Failure.. How to Diagnose

Lone messaegs of this type can be regarded as informational.

Solution

Check for 3com switch presence.

Customers should verify the status of other SL8500s in the complex. Look on the Error, Warn, Info logs (under Reports) for communication failures and for timeout messages (please refer to docs 1484207.1 and 1293137.1).

3com failure can also be indicated by frequent multiple failures to CSM components although this is not conclusive (please refer to docs 1484207.1 and 1293137.1).

 

 


 

References

<NOTE:1472641.1> - SL8500 - 3-Comm Switch Failure, PUE Replacement
<NOTE:1293137.1> - SL8500 - IP Switch Failure.. How to Diagnose
<NOTE:1449302.2> - Information Center: Sun StorageTek SL8500 Modular Library System
<NOTE:1484207.1> - SL8500 - Internal Ethernet 3Com Lan Switch or ILC 3Com Switch Does Not Power Up After Being Powered Down or Intermittent Communication Errors With Various Components in Library