![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1508154.1 : Bad Output from Uptime Command on T2000
Uptime command shows a high value that is inconsistent with the real time of the server. In this Document
Created from <SR 3-6399810941> Applies to:Sun Fire T2000 Server - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. SymptomsWhen the uptime command is executed, the output shows a value as follows: bash-3.00# uptime
7:36 am up 4690 day(s), 10:14, 2 users, load average: 0.59, 0.66, 0.61 Even after reboots, the problem persists. CauseAccording to Wayne Titchen (wayne.titchen@oracle.com), this issue is being reviewed since there is a second bug which impacts in the solution. Here are 2 bug's relating to the same issue: The suggested action plan in this case is: - Update to the new firmware and reset the ALOM date, and the HOST date: As soon as the correct solution is available, this document will be updated.
This issue is related to Bug 6496088: Bad output from uptime and prstat with LDoms firmware SolutionIt was fixed by Sun Fire T2000 Sun System Firmware 6.4.6 flashprom update. Current patch level should be applied: Sun System Firmware 6.7.13
REFERENCES: Document 1333450.1 - Sun Fire T2000 Firmware and Patches
Attachments This solution has no attachment |
||||||||||||||||||
|