Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1507911.1
Update Date:2017-09-25
Keywords:

Solution Type  Problem Resolution Sure

Solution  1507911.1 :   L180/L700/L1400 : Cap Open/Close issues  


Related Items
  • Sun StorageTek L700 Tape Library
  •  
  • Sun StorageTek L180 Tape Library
  •  
  • Sun StorageTek L1400 Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-6459665462>

Applies to:

Sun StorageTek L700 Tape Library - Version Not Applicable to Not Applicable [Release N/A]
Sun StorageTek L180 Tape Library - Version Not Applicable to Not Applicable [Release N/A]
Sun StorageTek L1400 Tape Library - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

CAP does not OPEN - When CAP button is pressed, CAP door opens but within few seconds closes again.

OR

CAP does not CLOSE - When CAP button is pressed, CAP door closes but within few seconds opens again.

------------ FSC # 3788 (hex) --------------
  SEVERITY : Warning
  MECHANISM : CAP_A
  OCCURRENCES : 24
  LAST OCCURRENCE : 11/16/2012    : 17:6:30
  TEXT : The CAP could not be opened. Check for obstacles and proper connections.

------------- FSC # 3787 (hex) --------------
 SEVERITY : Warning
 MECHANISM : CAP_A
 OCCURRENCES : 21
 LAST OCCURRENCE : 11/17/2012    : 13:22:53
 TEXT : The CAP could not be closed. Check for obstacles and proper connections.

Changes

 None

Cause

Defective OPEN/CLOSE CAP switch.

Solution

The above mentioned FSCs alone DOES NOT confirm switch failures.
Switch problems are relatively rare & hence eliminate other possible causes by following the normal CAP troubleshooting procedures.

If you suspect the switch, try below methods for testing :

On top of each CAP, there are 2 micro switches fitted below the metallic plate (see the attached pic).
One gets engaged when CAP is fully closed and other when CAP is fully open.

If one of the switch is faulty :

FE can easily swap these switch positions and problem should move from "NOT OPENING" to "NOT CLOSING" or vise versa.
OR
Use the switch set from other CAP or from other L180/L700/L1400 Libraries for testing.

In case you need replace the spare, below is the P/N. It inclused cables & switches.

419703001 [F] CBL ASSY,OPEN/CL,CAP

NOTE :
Replacing switch would not help if there is a obstruction and CAP door does not move enough to make contact with the switch.


Attachments