![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1507836.1 : Pillar Axiom: Windows host can lose access to mapped LUNs when a SAN Control Unit warmstarts
In this Document
Created from <SR 3-5970160311> Applies to:Pillar Axiom 600 Storage System - Version Not Applicable to Not Applicable [Release N/A]Pillar Axiom 500 Storage System - Version Not Applicable to Not Applicable [Release N/A] Pillar Axiom 300 Storage System - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. SymptomsIn a particular case, the storage administrator was using SAN RepLite that caused SAN Slammer 1 CU 1 to restart because of iSCSI overload on the iSCSI card. CauseControl Unit warmstarts in excess of 10 seconds and the MPIO driver considers the LUN as faulted. Solutionhttp://technet.microsoft.com/en-us/library/ee619749%28WS.10%29.aspx
Attachments This solution has no attachment |
||||||||||||||||
|