Asset ID: |
1-72-1506525.1 |
Update Date: | 2012-11-26 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1506525.1
:
Pillar Axiom: CIFS mounted shares on UNIX only list up to 87 files/dirs.
Related Items |
- Pillar Axiom 600 Storage System
|
Related Categories |
- PLA-Support>Sun Systems>DISK>Axiom>SN-DK: Ax600
|
In this Document
Created from <SR 3-5835177651>
Applies to:
Pillar Axiom 600 Storage System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Symptoms
Directory listings on CIFS mounted shares on UNIX only list up to 87 files/dirs. Other files/dirs exist, and one can use them if the name is known, but they can't be listed.
Cause
SW defect in Axiom
Solution
New Axiom Release adds support for "SMB_FIND_ID_FULL_DIRECTORY_INFO Level in Trans2 Find Next handler"
Fixed in Release 4.6.7. See DEFECT/BUG: 14558455
References
<BUG:14558455> - "LS" COMMAND IN RHEL 6.0 AND DEBIAN 6.0 CIFS CLIENTS DO NOT SHOW ALL FILES
Attachments
This solution has no attachment