Solution Type  Problem Resolution Sure

Solution  1505893.1 :   Exadata: Verify-topology Returned Some Errors Or Warning.  


Related Items
  • Exadata X5-2 Hardware
  •  
  • Exadata X3-2 Hardware
  •  
  • Exadata Database Machine X2-2 Hardware
  •  
  • Exadata X4-2 Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  




Created from <SR 3-6420922326>

Applies to:

Exadata Database Machine X2-2 Hardware - Version All Versions to All Versions [Release All Releases]
Exadata X4-2 Hardware
Exadata X3-2 Hardware
Exadata X5-2 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

verify-toplogy on a full X2-2 rack connected to QTR ExaLogic rack via Infiniband fails with the error below.


[ DB Machine Infiniband Cabling Topology Verification Tool ]
[Version IBD VER 2.c ]
External non-Exadata-image nodes found: check for ZFS if on T4-4 - else ignore
Spine switch found: leaf:1 (10e00b4840c0a0)
Leaf switch found: xxxxx-ib2.xxxxxx.com (2128f5729fa0a0)
Spine switch found: leaf:2 (10e00b9820c0a0)
Spine switch found: xxxxx-ib1.xxxxxx.com (2128f57247a0a0)
Leaf switch found: xxxxx-ib3.xxxxxx.com (2128f57235a0a0)

Found 2 leaf, 3 spine, 0 top spine switches

Check if all hosts have 2 CAs to different switches...............[SUCCESS]
Leaf switch check: cardinality and even distribution..............[SUCCESS]
Spine switch check: Are any Exadata nodes connected ..............[SUCCESS]
Spine switch check: Any inter spine switch links..................[ERROR] 

 

Cause

Verify-topology cannot be used with a mixed, multirack scenario like the above (interconnected exadata and exalogic racks).

As soon as any sort of Exalogic rack is mixed with any sort of Exadata rack, this renders verify-topology useless as it doesn't understand this setup. the engineering hasn't been done to make that work between different rack types.

Solution

Therefore, you can safely ignore any errors produced by verify-topology.


 