Server panic after installing Oracle FCoE CNA cards in Solaris 10 M5000 server
Related Items |
- Sun SPARC Enterprise M5000 Server
|
Related Categories |
- PLA-Support>Sun Systems>DISK>HBA>SN-DK: FC HBA
|
In this Document
Created from <SR 3-6425414851>
Applies to:
Sun SPARC Enterprise M5000 Server - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Server panic with following messages:
- Fatal error has occured in: PCIe fabric.(0x1)(0x41)
- fma SUNW-MSG-ID: SUNOS-8000-0G
- CNA card messages:
WARNING: qlc(2): failed to initialize adapter
WARNING: qlc(0): failed to initialize adapter
Changes
Installation of 2 new
SG-XPCIEFCOE2-Q-TA 375-3682 Dual 10-Gigabit Ethernet PCI Express LP SFP+ FCoE CNA cards
Cause
Installation of 2 new
SG-XPCIEFCOE2-Q-TA 375-3682 Dual 10-Gigabit Ethernet PCI Express LP SFP+ FCoE CNA cards
into a
SPARC Enterprise M5000 Server
OBP 4.33.5.a 2012/01/13 15:05
Solaris 10 10/09 s10s_u8wos_08a SPARC
without required/minimum patches 143957-03 and 144486-03
Listed in following documentation and issue was resolved by installing the patches.
Sun Storage 10GbE FCoE PCIe Converged Network Adapter Installation Guide For Adapter
Models SG-XPCIEFCOE2-Q-SR, SG-PCIEFCOE2-Q-SR, SG-XPCIEFCOE2-Q-TA, and SG-PCIEFCOE2-Q-TA
SG-XPCIEFCOE2-Q-SR/7053422 375-3681
SG-XPCIEFCOE2-Q-TA/7053423 375-3682
both
http://docs.oracle.com/cd/E19613-01/pdf/E20763.pdf
Solution
Install required/minimum patches per installation guide when installing FCoe CNA cards in any server.