Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1504348.1
Update Date:2017-09-21
Keywords:

Solution Type  Problem Resolution Sure

Solution  1504348.1 :   SL3000/SL8500 - FRS 8.01 and FRS-4.0 Codes Expire SLConsole Session after 6 Hours  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential to Service Personnel Only

Applies to:

Sun StorageTek SL3000 Modular Library System - Version Not Applicable and later
Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

 FRS 8.01 and FRS-4.0 Codes Expire SLConsole Session after 6 Hours

Changes

Upgraded library firmware.

Cause

 Due to Oracle security standards, new SL8500 and SL3000 codes will timeout an SLConsole session after 6 hours. This will require logging in again after the 6 hour period.

Solution

Due to Oracle security standards, new SL8500 and SL3000 codes will timeout an SLConsole session after 6 hours. This will require logging in again after the 6 hour period. This time can be extended to 1 week (168 hours)by entering the following command from a "service" login:

SL8500> config pliAuth set 168

 Possible values for the "hours" parameter are 6, 24, 48, 72 or 168 - The default value is 6.

This timeout behavior:

  • Affects both local and remote SLConsole sessions.
  • Affects all user IDs (service, admin etc).
  • Affects a CLI login.

 


Attachments