Solution Type Problem Resolution Sure Solution 1502146.1 : Sun SPARC Enterprise T5440 Server: Power system fault detected at /SYS/MB/CPUx/DVRM_15: status 0x4
fault detected at /SYS/MB/CPU0/DVRM_15: status 0x4 In this Document
Applies to:Sun SPARC Enterprise T5440 Server - Version All Versions and laterInformation in this document applies to any platform. SymptomsDuring HOST power on/off (ILOM cli, start /SYS or stop /SYS), D210 DC/DC Converter on some cpu modules have a false 00VP trip, which is reported as a (DVRM_15/00V_+1V5) asserted failure that is captured by firmware. The SP then power cycles the host. example (from ALOM-CMT's "showlogs -v"): Chassis |critical: "Host has been powered off" CauseThe DVRM_15: status 0x4 power system fault occurs when the D210 OE is disabled, causing the D210 on cpu modules to have a false OOVP (over voltage status bit) to be set for a short time that is captured by system firmware. The firmware then power cycles the host and turns the system back on again
Reference Alert doc: 1503151.1
SolutionIssue is fixed with firmware release 7.4.4.f (patch number 147311-05). Recommend firmware upgrade ASAP. Attachments This solution has no attachment |
||||||||||||||||
|