Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1502146.1
Update Date:2018-01-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  1502146.1 :   Sun SPARC Enterprise T5440 Server: Power system fault detected at /SYS/MB/CPUx/DVRM_15: status 0x4  


Related Items
  • Sun SPARC Enterprise T5440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5xx0
  •  


fault detected at /SYS/MB/CPU0/DVRM_15: status 0x4

In this Document
Symptoms
Cause
Solution


Applies to:

Sun SPARC Enterprise T5440 Server - Version All Versions and later
Information in this document applies to any platform.

Symptoms

During HOST power on/off  (ILOM cli, start /SYS or stop /SYS), D210 DC/DC Converter on some cpu modules have a false 00VP trip, which is reported as a (DVRM_15/00V_+1V5) asserted failure that is captured by firmware.  The SP then power cycles the host. 


example (from ALOM-CMT's "showlogs -v"):

Chassis |critical: "Host has been powered off"
Chassis |major : "/SYS/MB/CPU0/DVRM_15/OOV_+1V5: asserted failure"
Chassis |major : "Power system fault detected at /SYS/MB/CPU0/DVRM_15: status 0x4"
Fault |critical: "SP detected fault at time Mon Jul 11 14:04:26 2011. Host Power Failure: MB_DC_POK Fault"

Cause

The DVRM_15: status 0x4 power system fault occurs when the D210 OE is disabled, causing the D210 on cpu modules to have a false OOVP (over voltage status bit) to be set for a short time that is captured by system firmware. The firmware then power cycles the host and turns the system back on again

 

CR 7080248

Reference Alert doc: 1503151.1

 

Solution

 Issue is fixed with firmware release 7.4.4.f (patch number 147311-05).  Recommend firmware upgrade ASAP.