![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1501902.1 : Exadata: After disk replacement cellcli -e list physicaldisk shows old disk as Not Present even after 7 days and also shows duplicate slot numbers
Created from <SR 3-6364317611> Applies to:Exadata Database Machine X2-2 Hardware - Version All Versions and laterOracle Exadata Hardware - Version 11.2.0.3 and later Information in this document applies to any platform. SymptomsAfter a disk replacement the old disk still shows up as 'Not Present' ChangesDisk has been replaced. CauseA possible cause is: Unpublished Bug:13019838 REPLACED FAILED PHYSICAL DISK STILL SHOW STALE STATUS AS "NOT PRESENT" SolutionRestart the MS server: cellcli >alter cell restart services MS References<BUG:13019838> - REPLACED FAILED PHYSICAL DISK STILL SHOW STALE STATUS AS "NOT PRESENT"Attachments This solution has no attachment |
||||||||||||
|