Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1501902.1
Update Date:2014-03-07
Keywords:

Solution Type  Problem Resolution Sure

Solution  1501902.1 :   Exadata: After disk replacement cellcli -e list physicaldisk shows old disk as Not Present even after 7 days and also shows duplicate slot numbers  


Related Items
  • Oracle Exadata Hardware
  •  
  • Exadata Database Machine X2-2 Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  
  • _Old GCS Categories>ST>Server>Engineered Systems>SPARC SuperCluster>Exadata Storage Cells Hardware
  •  




Created from <SR 3-6364317611>

Applies to:

Exadata Database Machine X2-2 Hardware - Version All Versions and later
Oracle Exadata Hardware - Version 11.2.0.3 and later
Information in this document applies to any platform.

Symptoms

 After a disk replacement the old disk still shows up as 'Not Present'

Changes

Disk has been replaced.

Cause

 A possible cause is:

Unpublished Bug:13019838 REPLACED FAILED PHYSICAL DISK STILL SHOW STALE STATUS AS "NOT PRESENT"

Solution

 Restart the MS server:

cellcli

>alter cell restart services MS

References

<BUG:13019838> - REPLACED FAILED PHYSICAL DISK STILL SHOW STALE STATUS AS "NOT PRESENT"

Attachments
This solution has no attachment