![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1500832.1 : Exadata: CELL-04582: An error was encountered while populating the disk
Created from <SR 3-6243956721> Applies to:Exadata Database Machine X2-2 Hardware - Version All Versions and laterOracle Exadata Storage Server Software - Version 11.2.2.4.2 to 11.2.3.1.0 [Release 11.2] Information in this document applies to any platform. SymptomsThis issue could happen at the time of rolling upgrade from say 11.2.2.4.2 to 11.2.3.1.1 or after replacing a bad disk. After reboot of cell the error could be :-
Cellcli commands give error below :- #cellcli -e 'list griddisk attributes name,status,asmmodestatus,asmdeactivationoutcome' List lun disk, list celldisk also give the error :- CELL-04582: An error was encountered while populating the disk.
CauseWhen one FDOM is having problem ,cellsrv or MS should mark it as not present and should proceed further with all the available disks, instead of preventing any command to execute and giving no access to any disk at all in the cell From /var/log/messages we can see: .. MS was running, recreating flashcache did not fix the problem. See the note Exadata Write-Back Flash Cache - FAQ <Document 1500257.1> and the Documentation for more details about the syntax. system could have a bad flash card with IO errors, and it needs replacement as it has disappeared from the OS. SolutionReplace the failing flash card. Once the bad flash card was replaced with a good one, all cellcli commands started working & flashcache size was also showing up correctly References<BUG:14674493> - CAN NOT LIST GRIDDISK/CELLDISK/PHYSICALDISK - CELL-04582Attachments This solution has no attachment |
||||||||||||
|