![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1496245.1 : Failed Drive Alarm May Not Clear Automatically After Drive Replacement When Drive is Assigned to an Empty VDISK
In this Document
Applies to:Sun Storage 2530-M2 Array - Version Not Applicable to Not Applicable [Release N/A]Sun Storage 2540 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 2540-M2 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage Flexline 380 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 6540 Array - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. SymptomsAfter a failed disk drive is replaced, the new disk reports as Optimal, however, the alarm for the disk failure never clears.
Event Code : XX.66.1023
Description : Drive Tray.YY.Drive.ZZ failed. This problem is only known to occur in 25x0 and 6xx0 arrays running 7.x versions of controller firmware.
ChangesThe failed Disk Drive was replaced in the array. CauseThe problem occurs when the disk is a member of a Virtual Disk (aka Volume Group) that has NO associated volumes. Since there is no data to reconstruct, the array does not clear the failed drive condition. Solution
Note: so long as no volumes are associated with the Virtual Disk - no data will be lost.
Wait for at least 5 minutes for the problem to clear, if the problem persists, please contact Oracle support for further assistance. Attachments This solution has no attachment |
||||||||||||||||||
|