![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1494017.1 : GW command showgwports: shows "Line 69, In ? Iport(i, Port) ValueError: Failed To Get Iport Attr"
In this Document
Created from <SR 3-6202874271> Applies to:Oracle Exalogic Elastic Cloud X2-2 Hardware - Version All Versions and laterLinux x86-64 Oracle Solaris on x86-64 (64-bit) SymptomsWhen running the command showgwports in one of the NM2-GW switches, resulting following error:
[root@elorl01gw01-adm ~]# showgwports
INTERNAL PORTS: --------------- Device Port Portname PeerPort PortGUID LID IBState GWState --------------------------------------------------------------------------- Bridge-0 1 Bridge-0-1 4 0x002128c376fac001 0x000b Active Up Bridge-0 2 Bridge-0-2 3 0x002128c376fac002 0x002f Active Up Traceback (most recent call last): File "/usr/local/bin/showgwports", line 69, in ? iport = pydcsgw.getiport(i, port) ValueError: Failed to get iport attrs Ideally, the epxected the output should be: [root@elorl01gw01-adm ~]# showgwports
ChangesThe issue was faced on InfiniBand Gateway Switch (NM2-GW), firmware version 2.0.4-1 [root@elorl01gw01-adm ~]# version
SUN DCS gw version: 2.0.4-1 Build time: Oct 17 2011 10:04:07 FPGA version: 0x34 SP board info: Manufacturing Date: 2010.12.31 Serial Number: "XXXXXXXXX" Hardware Revision: 0x0006 Firmware Revision: 0x0000 BIOS version: SUN0R100 BIOS date: 06/22/2010
CauseThis is a known issue and resolved through the (Sun CR 7167619) Bug 15790691 SolutionThe fix went into the version 2.1.2. Till the fix is available, a feasible solution is to restart the switch in question. References<BUG:15790691> - SUNBT7167619-2.1.2 SHOWGWPORTS FAILS WITH "BXM_EOIB_GET_VLAN_TO_PKEY_MAP() CALLAttachments This solution has no attachment |
||||||||||||||||||||
|