Symptoms

When running the command showgwports in one of the NM2-GW switches, resulting following error:

 

[root@elorl01gw01-adm ~]#  showgwports

INTERNAL PORTS:
---------------

Device   Port Portname  PeerPort PortGUID           LID    IBState  GWState
---------------------------------------------------------------------------
Bridge-0  1   Bridge-0-1    4    0x002128c376fac001 0x000b Active   Up
Bridge-0  2   Bridge-0-2    3    0x002128c376fac002 0x002f Active   Up
Traceback (most recent call last):
File "/usr/local/bin/showgwports", line 69, in ?
iport = pydcsgw.getiport(i, port)
ValueError: Failed to get iport attrs

 Ideally, the epxected the output should be:

[root@elorl01gw01-adm ~]#  showgwports

INTERNAL PORTS:
---------------

Device    Port  Portname  Peer Port   PortGUID                LID    IBState  GWState
------------------------------------------------------------------------------------------------------
Bridge-0   1    Bridge-0-1     4       0x002128c376fac001 0x000b  Active    Up
Bridge-0   2    Bridge-0-2     3       0x002128c376fac002 0x002f   Active    Up
Bridge-1   1    Bridge-1-1     2       0x002128c376fac041 0x0035  Active    Up
Bridge-1   2    Bridge-1-2     1       0x002128c376fac042 0x0055  Active    Up

CONNECTOR 0A-ETH:
-----------------

Port               Bridge      Adminstate   Link    State      Linkmode    Speed
--------------------------------------------------------------------------------------------
0A-ETH-1   Bridge-0-2   Enabled     Up       Up           XFI            10Gb/s
0A-ETH-2   Bridge-0-2   Enabled     Up       Up           XFI            10Gb/s
0A-ETH-3   Bridge-0-1   Enabled     Down   Reset       XFI            10Gb/s
0A-ETH-4   Bridge-0-1   Enabled     Down   Reset       XFI            10Gb/s

CONNECTOR 1A-ETH:
-----------------

Port               Bridge      Adminstate   Link    State      Linkmode    Speed
--------------------------------------------------------------------------------------------
1A-ETH-1    Bridge-1-2   Enabled    Down   Reset       XFI            10Gb/s
1A-ETH-2    Bridge-1-2   Enabled    Down   Reset       XFI            10Gb/s
1A-ETH-3    Bridge-1-1   Enabled    Down   Reset       XFI            10Gb/s
1A-ETH-4    Bridge-1-1   Enabled    Down   Reset       XFI            10Gb/s

 

Changes

 The issue was faced on InfiniBand Gateway Switch (NM2-GW), firmware version 2.0.4-1

[root@elorl01gw01-adm ~]# version
SUN DCS gw version: 2.0.4-1
Build time: Oct 17 2011 10:04:07
FPGA version: 0x34
SP board info:
Manufacturing Date: 2010.12.31
Serial Number: "XXXXXXXXX"
Hardware Revision: 0x0006
Firmware Revision: 0x0000
BIOS version: SUN0R100
BIOS date: 06/22/2010

 

Cause

This is a known issue and resolved through the (Sun CR 7167619) Bug 15790691
 

Solution

The fix went into the version 2.1.2. Till the fix is available, a feasible solution is to restart the switch in question.
 

References

<BUG:15790691> - SUNBT7167619-2.1.2 SHOWGWPORTS FAILS WITH "BXM_EOIB_GET_VLAN_TO_PKEY_MAP() CALL