Solution  1491902.1 :   SL8500 - Elevator Initialization Error, Result Code 7012  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential to Service Personnel Only

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Elevator fails to initialize.

RC7012, Result code 7012

Error 3955

2012-08-23T07:46:40.866    1.0.54.2.0    root    default    internal    0    error    3955    "Error from device Code: 701 - Move failed - Device inoperative"  Data=<response sequence="324129" final="true"><command>initialize</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>7012</resultCode><resultText><!|CDATA|Bad init range for vaderb: actual=55835 mils, expected=56869 +/- 600; ||></resultText><operationalState>701</operationalState></resultStatus></result></response>    UNKNOWN

The elevator would go all the way up and then all the way down and then fail.  This generally eliminates the HBZ and motor as suspects.

Cause

 The problem was the metal tab on the rear of the elevator array was bent and hitting the lower clamping collar that retains the column. This caused the short travel noted in the log.

Solution

Bend the tab slightly to resolve the problem.

Provided by Richard Kent