Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1484207.1
Update Date:2017-09-21
Keywords:

Solution Type  Problem Resolution Sure

Solution  1484207.1 :   SL8500 - Internal Ethernet 3Com Lan Switch or ILC 3Com Switch Does Not Power Up After Being Powered Down or Intermittent Communication Errors With Various Components in Library  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential to Service Personnel Only

Applies to:

Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

Majority of components within the SL8500 communicate with the HBC/HBCR card via the internal Lan switch, examples; HBT-->HBCR, HBZ-->HBCR, PTP-->HBCR. The exception is rail communication which uses the rail-net via the HBS module. If components are not able to communicate with the Library Controller HBCR card operations will be severely impacted or stop completely but the Handbots all appear to be online.

No LEDs illuminated on the internal 3Com switch or the ILC switch, not able to login to the local Operator Panel but can login remotely, missing drive folder in the SLC device tree, Cap and/or elevator missing or has a red icon in the SLC device tree, all mounts stop occurring, PTP operations stop or go offline in SLC, etc.  

Cause

Defective power supply inside the original 3Com switch or other internal failure. 

Solution

Upgrade to the 2nd generation Ethernet Switch; PUE PN_419951602 <PN_7025036> during the next scheduled maintenance window.

The PUE is a 32 port switch with dual power supplies that eliminates the need for the APC AC switch for 2N power configuration support.

Note: The internal Lan switch is located in the top right quadrant of the DEM behind the smoke detector.

Refer to the attached file for PUE Conversion Bill Installation Instructions.

Provided by Bruce McDonald.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback