![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1481290.1 : Sun StorageTek[TM] 5320 NAS: Amber Service LED ON and 'no evidence' of H/W problem (battery issue)
In this Document
Created from <SR 3-5963396371> Applies to:Sun Storage 5320 NAS Appliance - Version All Versions and laterSun Storage 5320 NAS Cluster - Version All Versions and later Sun Storage 5320 NAS Gateway - Version All Versions and later Information in this document applies to any platform. SymptomsService LED ON and 'no evidence' of hardware problem Changes
Cause
cat diag.txt file and check for voltage ~ Voltage levels Battery 3V : 0.60 V <<<
Stndby 3.3V : 3.26 V Main 3.3V : 3.30 V Main 5V : 4.99 V Main 12V : 12.15 V Main -12V : -12.27 V Main 2.5V : 2.54 V Main 1.8V : 1.82 V Main 1.2V : 1.21 V
-> show /SP/logs/event/list/ ID Date/Time Class Type Severity 43111 Mon Aug 6 12:12:31 2012 IPMI Log critical 43110 Mon Aug 6 12:12:26 2012 IPMI Log critical
-> show -d properties -level all /SYS /SYS/SERVICE /SYS/MB/V_BAT
SolutionReplace the battery part-number 150-3993 Note - This component is a CRU and can be replaced by anyone. http://docs.oracle.com/cd/E19121-01/sf.x4200/819-1157-23/Maint.html#0_pgfId-1000200
***Checked for relevance on 04-FEB-2014*** ***Checked for relevance on 04-JUL-2015* ***Checked for relevance on 23-FEB-2018***** References<NOTE:1009944.1> - Sun StorageTek[TM] 5320 NAS: Fault LED on Head Lights Up With No Apparent FaultAttachments This solution has no attachment |
||||||||||||||||||||
|