Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1480545.1
Update Date:2018-01-03
Keywords:

Solution Type  Problem Resolution Sure

Solution  1480545.1 :   HP LTO4 - Fibre Channel Drive Reports All Tapes As "Write Protected"  


Related Items
  • HP LTO4 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-6009884381>

Applies to:

HP LTO4 Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Oracle Solaris on SPARC (64-bit)

Symptoms

One drive sees tapes as "write protected".
Load / Unload failures detected on the same drive........Check the error warn info event log

Drive mechanism failed to "write enable" the tapes / Cartridges.. Tapes are perceived as "write protected"

Cause

Drive sensor is defective.

Solution

All tapes reported as "WRITE PROTECTED" when loaded.

Replaced the drive to fix this problem.
 