Exadata: Removing power from rack, system failed to power on after power was restored
Related Items |
- Oracle Platinum Services
- Exadata Database Machine V2
|
Related Categories |
- PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
|
In this Document
Applies to:
Exadata Database Machine V2
Oracle Platinum Services - Version N/A to N/A
Information in this document applies to any platform.
Symptoms
- Removing power from entire rack
- After restoring power to the rack, some systems remained power down
- Affects all image versions including 11.2.3.1.1
Cause
Unpublished <Bug 13578903>
Solution
Workaround
- Restart power of the servers throug the ILOM
- ipmitool -H <ILOM address> -U root -P <password> chassis power on