Solution Type  Problem Resolution Sure

Solution  1459762.1 :   SL500 - Base Module Cooling FAN Failures, Error 8011  


Related Items
  • Sun StorageTek SL500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
  •  




In this Document
Symptoms
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential to Service Personnel Only
Created from <SR 3-5615341151>

Applies to:

Sun StorageTek SL500 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

Both Fans in SL500 Base Module are failing. Fans were replaced but problem remains.

Event Logs show below entries :

----
2012-03-31T13:21:02.154,  0.0.0.0.0,  unknown,  default,  0000,  (null),  error,  8011,  "SensorFanFuncs: doModuleFanStatus - Module 1 fan 1 failure"
2012-03-31T13:21:07.489,  0.0.0.0.0,  unknown,  default,  0000,  (null),  error,  8011,  "SensorFanFuncs: doModuleFanStatus - Module 1 fan 2 failure"
---

Cause

RLM back plane has connectors J112 & J113 for 2 Base Module Fans. Blown Fuse on RLM can stop Fans from functioning.
 

Solution

If Fans are replaced already, replacing Blank RLM card is suggested.

Ensure to follow the RLM replacement procedure provided in the referred document below.
 

References

<NOTE:1019641.1> - SL500 - Non Pre-Programmed RLM Card Replacement Procedure