Solution Type  Problem Resolution Sure

Solution  1456283.1 :   ALOM console command hangs  


Related Items
  • Sun Fire V440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-V4x0
  •  


console from SC/ALOM does not connect when connecting via serial port and seems to hang 
All other SC/ALOM commands function and OS may be running without apparent issue

In this Document
Symptoms
Cause
Solution


Created from <SR 3-5650667501>

Applies to:

Sun Fire V440 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Connected via serial port on ALOM card

output-device=screen
input-device=keyboard

if changed to:

output-device=ttya
input-device=ttya

Problem still exists

Symptoms



To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - SPARC Legacy Servers



Console command does not connect to serial console

sc> console -f

<just hangs>

 

all other processes are working fine from both the OS and ALOM  

Cause

SC is unable to communiate with the OS console processes 

Solution

Restart (stop/start) ttymon or console services 

Solaris 10 - svcs
   

# svcadm disable console-login
# svcadm enable console-login

  

 